Indexed by:
Abstract:
Cascaded H-bridge (CHB) multilevel inverter has gained more and more focus due to its adaptability to high-power, high-voltage applications and capability of fault tolerant. Under the circumstance of instantaneous value feedback control, the magnetic biasing of the transformer is a problem of great significance. This paper shows the circumstances under which a transformer has to be used for the CHB multilevel inverter, and the adverse impact of the magnetic biasing of the transformer. Also, it analyses the mechanism of the occurrence of the DC component in output voltage which causes the magnetic biasing, then the carrier phase shifted modulation strategy of the CHB multilevel inverter is discussed. Finally, this paper proposes a novel control scheme with several advantages compared with other control schemes which can eliminate the magnetic biasing of the transformer. The experiment results are carried out which verifies the advantages and feasibility of the proposed control scheme. © 2012 IEEE.
Keyword:
Reprint Author's Address:
Source :
Conference Proceedings - 2012 IEEE 7th International Power Electronics and Motion Control Conference - ECCE Asia, IPEMC 2012
ISSN: 9781457720864
Year: 2012
Publish Date: 2012
Volume: 3
Page: 1965-1970
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count: 5
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: