Long-term accelerated aging test of generator stator insulation in the laboratory was conducted. Nondestructive parameters, such as dissipation factor (tan delta), capacitance (C) and the voltage (U-i2) at which the current increases abruptly, were measured in the period of aging test. The breakdown test was performed to determine residual breakdown voltage (BDV). The correlation coefficients between BDV and nondestructive parameters were compared, The most effective parameter to describe the aging condition of the stator insulation was U-i2. In this paper, the relationship between BDV and nondestructive parameters was analyzed theoretically.