Xie, Shejuan (Xie, Shejuan.) | Tian, Mingming (Tian, Mingming.) | Pei, Cuixiang (Pei, Cuixiang.) | Chen, Hong-En (Chen, Hong-En.) | Chen, Zhenmao (Chen, Zhenmao.) (Scholars:陈振茂) | Takagi, Toshiyuki (Takagi, Toshiyuki.)

Indexed by:

CPCI-S EI Scopus

Abstract:

In this paper, a hybrid nondestructive testing (NDT) method combined with the pulsed eddy current testing (PECT) method and the electromagnetic acoustic transducer (EMAT) method has been proposed and validated through numerical simulations and experiments. First, a numerical code is developed for the simulation of hybrid EMAT/PECT signals. Second, based on the numerical simulation, the influences of the eddy current induced by the excitation coil and the eddy current due to the velocity effect of the ultrasonic wave are compared and analyzed. Third, several signal separation and extraction methods are proposed on the basis of the spectral analysis and filtering strategies. Finally, hybrid EMAT/PECT experiments are conducted. Based on the numerical and experimental results, the proposed hybrid PECT/EMAT NDT method is demonstrated both high detectability and high efficiency.

Keyword:

Composite defects EMAT Hybrid NDT method PECT Signal separation and extraction

Author Community:

  • [ 1 ] [Xie, Shejuan; Tian, Mingming; Pei, Cuixiang; Chen, Hong-En; Chen, Zhenmao] Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 2 ] [Takagi, Toshiyuki] Tohoku Univ, Inst Fluid Sci, Innovat Energy Res Ctr, Aoba Ku, Sendai, Miyagi 9808577, Japan
  • [ 3 ] [Xie, Shejuan]Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 4 ] [Tian, Mingming]Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 5 ] [Pei, Cuixiang]Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 6 ] [Chen, Hong-En]Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 7 ] [Chen, Zhenmao]Xi An Jiao Tong Univ, Shaanxi ERC NDT & Struct Integr Evaluat, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
  • [ 8 ] [Takagi, Toshiyuki]Tohoku Univ, Inst Fluid Sci, Innovat Energy Res Ctr, Aoba Ku, Sendai, Miyagi 9808577, Japan

Reprint Author's Address:

  • 陈振茂

    Xi An Jiao Tong Univ, State Key Lab Strength & Vibrat Mech Struct, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China.

Show more details

Related Keywords:

Source :

ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XX)

ISSN: 1383-7281

Year: 2017

Volume: 42

Page: 139-149

Language: English

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 10

FAQ| About| Online/Total:1569/168878145
Address:XI'AN JIAOTONG UNIVERSITY LIBRARY(No.28, Xianning West Road, Xi'an, Shaanxi Post Code:710049) Contact Us:029-82667865
Copyright:XI'AN JIAOTONG UNIVERSITY LIBRARY Technical Support:Beijing Aegean Software Co., Ltd.