Indexed by:
Abstract:
With the extensive use of room air conditioners, their refrigerants have a greater impact on the environment. Among many alternative refrigerants, R290 is environmentally friendly and energy-saving. Furthermore, the dynamic characteristics of R290 split room air conditioners are different from those of HFCs and HCFCs air conditioners. In previous research of R290 split room air conditioners, abnormal system parameters frequently occurred in heating and defrosting process. In this paper, the abnormal phenomena are determined to be caused by the oil blockage of throttle component. Especially, the failure often leads to safety problems of air conditioner. In addition, the abnormal phenomena of a R290 split room air conditioner was reproduced in the enthalpy difference chamber. The influence factors of the failure were studied experimentally and the experimental results showed that the oil blockage of EEV are mainly affected by the working conditions, the type of lubricating oil and the opening of EEV, which will provide experimental basis for further mechanism analysis and solution. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
ISSN: 0140-7007
Year: 2020
Volume: 112
Page: 14-20
3 . 6 2 9
JCR@2020
3 . 6 2 9
JCR@2020
ESI Discipline: ENGINEERING;
ESI HC Threshold:59
JCR Journal Grade:2
CAS Journal Grade:2
Cited Count:
WoS CC Cited Count: 3
SCOPUS Cited Count: 11
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: