Abstract:
The principle and preparation method of the ion-exchange technology used in surface-conduction electron emitters is introduced in this paper. Surface-conduction electron emitters through the use of ion-exchange technology were developed. The relationships between device current and emission current on device voltage has been determined. The electronic emission characteristic of surface-conduction electron emitters were also determined. The results indicate that the relationship between emission current and device voltage is non-linear. A device-voltage range between 20 and 27 V results in the best emission efficiency.