Abstract:

The maldistribution of two-phase flow is one of the major factors that deteriorate the heat transfer performance of plate-fin heat exchanger. The set-up of flow distributor at the heat exchanger inlet is one widely adopted engineering method to improve the flow distribution. In this paper the flow distribution performance of one type of distributor is experimentally tested by using air-water mixture. The test results show that the flow distributor studied can improve the two-phase flow distribution uniformity in plate-fin heat exchanger. © All Rights Reserved.

Keyword:

Air-water mixture Distributor Engineering methods Flow distributors Heat transfer performance Plate-fin heat exchanger Two-phase flow distribution Uniform

Author Community:

  • [ 1 ] [Yuan, Pei;Jiang, Guobao;Zhang, Feini;He, Yaling;Tao, Wenquan]School of Energy and Power Engineering, State Key Laboratory of Multi-phase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi, China
  • [ 2 ] [Tan, Minbang]Sichuan Air Separation Plant(Group) Company, Jianyang 641400, Sichuan, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

Huagong Xuebao/CIESC Journal

ISSN: 0438-1157

Year: 2011

Issue: SUPPL. 1

Volume: 62

Page: 31-36

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 2

FAQ| About| Online/Total:1027/168835572
Address:XI'AN JIAOTONG UNIVERSITY LIBRARY(No.28, Xianning West Road, Xi'an, Shaanxi Post Code:710049) Contact Us:029-82667865
Copyright:XI'AN JIAOTONG UNIVERSITY LIBRARY Technical Support:Beijing Aegean Software Co., Ltd.