Indexed by:
Abstract:
Experimental study on non-equilibrium characteristics of circulatory flash evaporation was present. The tests were conducted at superheat from 0 to 30 K, flash evaporation pressure of 0.0124, 0.0199 and 0.0311 MPa, water flow rate of 0.11, 0.17 and 0.22 L/s, initial waterfilm height of 140 and 180 mm. The experimental results show that Non-equilibrium fraction (NEF) decreases with the increase of pressure and the increase of water flow rate, but increases with the increase of initial waterfilm height. Based on the experimental results analysis, a correlation about the non-equilibrium fraction with all the influencing factors are present.
Keyword:
Reprint Author's Address:
Email:
Source :
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
ISSN: 0253-231X
Year: 2013
Issue: 11
Volume: 34
Page: 2093-2096
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1